5.11. SEQUENCE
(GENERATOR
)
A sequence or a generator is a database object used to get unique number values to fill a series.
Sequence
is the SQL-compliant term for the same thing which, in Firebird, has traditionally been known as generator
.
Both terms are implemented in Firebird, which recognises and has syntax for both terms.
Sequences (or generators) are always stored as 64-bit integers, regardless of the SQL dialect of the database.
If a client is connected using Dialect 1, the server sends sequence values to it as 32-bit integers. Passing a sequence value to a 32-bit field or variable will not cause errors as long as the current value of the sequence does not exceed the limits of a 32-bit number. However, as soon as the sequence value exceeds this limit, a database in Dialect 3 will produce an error. A database in Dialect 1 will keep cutting the values, which will compromise the uniqueness of the series.
This section describes how to create, set and delete sequences.
5.11.1. CREATE SEQUENCE (GENERATOR)
Used forCreating a new SEQUENCE
(GENERATOR
)
Available inDSQL, ESQL
Syntax
|
CREATE {SEQUENCE | GENERATOR} seq_name
CREATE SEQUENCE
| CREATE GENERATOR
Statement ParameterParameter | Description |
---|---|
seq_name | Sequence (generator) name. It may consist of up to 31 characters |
The statements CREATE SEQUENCE
and CREATE GENERATOR
are synonymous — both create a new sequence.
Either can be used but CREATE SEQUENCE
is recommended if standards-compliant metadata management is important.
When a sequence is created, its value is set to 0.
Each time the NEXT VALUE FOR seq_name
operator is used with that sequence, its value increases by 1.
The GEN_ID(seq_name, <step>)
function can be called instead, to step
the series by a different integer number.
Any user connected to the database can create a sequence (generator).
Creating the
EMP_NO_GEN
series usingCREATE SEQUENCE
.|
CREATE SEQUENCE EMP_NO_GEN;
Creating the
EMP_NO_GEN
series usingCREATE GENERATOR
.|
CREATE GENERATOR EMP_NO_GEN;
See alsoSection 5.11.2, “ALTER SEQUENCE
”, Section 5.11.3, “SET GENERATOR
”, Section 5.11.4, “DROP SEQUENCE (GENERATOR)
”, NEXT VALUE FOR
, GEN_ID() function
5.11.2. ALTER SEQUENCE
Used forSetting the value of a sequence or generator to a specified value
Available inDSQL
Syntax
|
ALTER SEQUENCE seq_name RESTART WITH new_val
ALTER SEQUENCE
Statement ParametersParameter | Description |
---|---|
seq_name | Sequence (generator) name |
new_val | New sequence (generator) value. A 64-bit integer from -2-63 to 263-1. |
The ALTER SEQUENCE
statement sets the current value of a sequence or generator to the specified value.
Incorrect use of the ALTER SEQUENCE
statement (changing the current value of the sequence or generator) is likely to break the logical integrity of data.
Any user connected to the database can set the sequence (generator) value.
Setting the value of the
EMP_NO_GEN
sequence to 145.|
ALTER SEQUENCE EMP_NO_GEN RESTART WITH 145;
Doing the same thing, using
SET GENERATOR
:|
SET GENERATOR EMP_NO_GEN TO 145;
See alsoSection 5.11.3, “SET GENERATOR
”, Section 5.11.1, “CREATE SEQUENCE (GENERATOR)
”, Section 5.11.4, “DROP SEQUENCE (GENERATOR)
”, NEXT VALUE FOR
, GEN_ID() function
5.11.3. SET GENERATOR
Used forSetting the value of a sequence or generator to a specified value
Available inDSQL, ESQL
Syntax
|
SET GENERATOR seq_name TO new_val
SET GENERATOR
Statement ParametersParameter | Description |
---|---|
seq_name | Generator (sequence) name |
new_val | New sequence (generator) value. A 64-bit integer from -2-63 to 263-1. |
The SET GENERATOR
statement sets the current value of a sequence or generator to the specified value.
Although SET GENERATOR
is considered outdated, it is retained for backward compatibility.
Using the standards-compliant ALTER SEQUENCE
is current and is recommended.
Any user connected to the database can set the sequence (generator) value.
Setting the value of the
EMP_NO_GEN
sequence to 145:|
SET GENERATOR EMP_NO_GEN TO 145;
Doing the same thing, using
ALTER SEQUENCE
:|
ALTER SEQUENCE EMP_NO_GEN RESTART WITH 145;
See alsoSection 5.11.2, “ALTER SEQUENCE
”, Section 5.11.1, “CREATE SEQUENCE (GENERATOR)
”
5.11.4. DROP SEQUENCE (GENERATOR)
Used forDeleting SEQUENCE
(GENERATOR
)
Available inDSQL, ESQL
Syntax
|
DROP {SEQUENCE | GENERATOR} seq_name
DROP SEQUENCE
| DROP GENERATOR
Statement ParameterParameter | Description |
---|---|
seq_name | Sequence (generator) name. It may consist of up to 31 characters |
The statements DROP SEQUENCE
and DROP GENERATOR
statements are equivalent: both delete an existing sequence (generator).
Either is valid but DROP SEQUENCE
, being current, is recommended.
The statements will fail if the sequence (generator) has dependencies.
Any user connected to the database can drop a sequence (generator).
ExampleDropping the EMP_NO_GEN
series:
|DROP SEQUENCE EMP_NO_GEN;
See alsoSection 5.11.1, “CREATE SEQUENCE (GENERATOR)
”, Section 5.11.2, “ALTER SEQUENCE